Healthcare Technology Starting Selftesting Automatics Ventilation Mhra Anaesthetics Machine
Min. Order: | 1 Piece |
---|---|
Port: | Shanghai, China |
Payment Terms: | T/T |
Similar Items
You May Like
Product Description
Company Info
Product Description
China factory medical factory OEM Service Wholesale Price
Anesthesia Machine with ventilator S6200A
Application
The Anesthesia machine makes a good performance in Intensive Care Units (ICU), Operation room, Anesthesiology Depart-ment and other departments. Professional design for adult, child and infant inhalation anesthesia and respiratory management.
Configuration
12.1" LCD touch screen
Displays the Ventilation parameters, Alarm information and Oscillogram.
High sensitivity touch screen ensures accurate and easy operation. Alternate button for dual control.
Electronic flowmeter
High precision flowmeter, instantly know the fresh gas flow to patient. O2 and N2O linkage device
ensure O2 concentration no less than 25%.
Bellow
Integrated bellow 0mL - 1500mL. Suitable for all range patients.
APL valve
Automatic decompression to ensure safety.
ETCO2
End-tidal carbon dioxide concentration monitoring, real-time understanding of the patient state.
Breathing Circuit
Integrated breathing circuit design.Breathing tube resistants high temperature sterilization.
Ensure easy operating and keep tidy.
Vaporizer
Accurately delivers a calibrated flow,
Halothane, Enflurane, Isoflurane, Sevoflurane for choice.
2 vaporizers for standard. Suitable for low flow anesthesia, save cost.
Pressure Gauge
Real time pressure for Air, O2, N2O from central gas supply and gas cylinders.
ACGO and Fast Oxygen Supply
Real time pressure for Air, O2, N2O from central gas supply and gas cylinders.
Optional Configuration
Anesthetic gas monitor, Vital Signs Monitor:Real-time monitoring of anesthetic gas and patient's physiological condition.
AGSS: To enhance the safety of the environment in which members of staff in close proximity
with waste anesthetic gases and vapors (agents) work.
Specifications
Ventilation modes: | IPPV; A/C; PCV; SIMV; SIGH |
Ventilator parameter ranges |
|
Flow meter | O2(0.1-10L/min) |
| N2O(0.1-10L/min) |
| AIR(0.1-10L/min) |
Rapid oxygen supply | 35L/min-75L/min |
Tidal volume(Vt) | 0, 20 mL ~ 1500 mL |
Frequence(Freq) | 1bpm ~ 100 bpm |
I/E | 4:1~1:8 |
PEEP | 0cmH2O ~ 30 cmH2O |
Pressure triggering sensitivity(PTr) | -20 cmH2O ~ 0 cmH2O(Based on PEEP) |
Flow trigger sensitivity (FTr) | 0.5 L/min ~ 30 L/min |
Pressure control (PC) | 5 cmH2O ~ 60 cmH2O |
SIGH | 0(off) 1/100 ~ 5/100 |
Apnea Ventilation | OFF,5 s ~ 60 s |
Pressure Limit | 20 cmH2O ~ 100 cmH2O |
Monitored Parameters |
|
Frequence(Freq) | 0 /min ~ 100 /min |
Tidal volume(Vt) | 0 mL ~ 2000 mL |
MV | 0 L/min ~ 100 L/min |
Oxygen concentration | 15 % ~ 100 %
|
Graphical display: |
|
P-T(pressure - time), F-T(flow - time), V-T(volume - time ),
|
|
The AC power failure alarm | Power failure or no connection |
Internal battery backup low voltage alarm | <11.3±0.3V |
No tidal volume | ≤5Ml within 6s |
High oxygen concentration alarm Low oxygen concentration alarm | 19%-100% 18%-99% |
High Airway pressure alarm Low Airway pressure alarm High Minute Volume alarm Low Minute Volume alarm Continuous Pressure alarm | 20cmH2O-100cmH2O 0cmH2O-20cmH2O Adult(5L/min-20L/min) Paed(1L/min-15L/min 0-10L/min) (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | <12.5 kPa |
Standard S6100 PLUS machine packed in one wooden case;
Size: 870 * W 890 * H 1510 mm GW:195 KG
Superstar Medical have specialzied in this field for 25 years, mainly focus on anesthesia machine icu ventilation and neonatal Cpap.These equipment widely used in operation room, icu department and
nursery room.
Our business line: Anesthesia System, Ventilator, Nitrous Oxide Sedation system, CPAP system, Sleep Therapy System etc.