S9130 Sleep Therapy Apnea BIPAP Machine
Main technical parameters of S9130 non-invasive ventilator
1. Performance characteristics
1. Use a 4.3-inch color LCD screen to display breathing parameters, alarm information and waveform diagrams;
2. The expanded 15.6-inch display can be rotated by 90 degrees, which is convenient for medical staff to observe in multiple directions, and can directly display the flow waveform and pressure waveform;
3. It is suitable for non-invasive respiratory ventilation patients with respiratory insufficiency, and can be used in home and medical environments.
4. High-performance imported fan, compact body, and the equipment comes with a humidifier to increase air humidity;
5. Optional trolley to facilitate the transfer between hospital beds;
6. Optional humidifier to heat and humidify the inhaled gas, improve comfort, and effectively prevent complications caused by obstruction caused by dry airway;
7. Possess the National Class III Medical Device Registration Certificate;
8. Standard lithium battery with a capacity of 28500mAh, which can work independently and continuously for ≥8 hours, and can work continuously for ≥2 hours with an external expansion screen;
9. Low pressure oxygen can be connected externally, and the oxygen concentration range is 30-50%;
10. Noise ≤45dB(A) under 10cmH2O pressure level.
2. Working conditions
1. Power supply: DC 24 V (-15 to +25 %), 2.5 A
2. Power adapter: AC input 100~240 V, frequency 50/60 HZ DC output 24 V, 2.5 A
3. Ambient temperature range +5 ~ +35 ºC
4. The relative humidity range is 15 ~ 95%
5. Atmospheric pressure range 830 ~ 1060 hPa
3. Breathing mode and function
1. Spontaneous breathing and time control automatic switching mode (S/T mode) [optional]
2. Time control mode (T mode)
3. Spontaneous breathing mode (S mode)
4. Continuous positive pressure ventilation mode (CPAP mode)
5. Pressure control mode (PC) [optional]
6. Pressure automatic titration function (AUTO) [optional]
7. Average capacity guarantee pressure support function (AVAPS) [optional]
Fourth, the main technical indicators
Tuning parameters
1. AVPAS on/off
2. Tidal volume 200 ~ 1500 mL step: 10 mL
3. Breathing rate 3 ~ 40 bpm step: 1 bpm
4. Inhalation time 0.0 ~ 3.0 S step: 0.1 S
5. Inspiratory pressure (IPAP) 4 ~ 30 cmH2O step: 0.5 cmH2O
6. Maximum suction pressure (IPAPMAX) 4 ~ 30 cmH2O step: 0.5 cmH2O
7. Minimum suction pressure (IPAPMIN) 4 ~ 30 cmH2O step: 0.5 cmH2O
8. Expiratory pressure (EPAP) 4 ~ 25 cmH2O step: 0.5 cmH2O
9. Continuous positive airway pressure (CPAP) 4 ~ 20 cmH2O step: 0.5 cmH2O
10. Pressure delay rise time 0 ~ 60 min Step: 1 min
11. The pressure rise time is automatically adjusted, 0.1 S ~ 0.6 S step: 0.1 S
12. Inhalation sensitivity automatic adjustment, 1, 2, 3 step: 1
13. Exhalation sensitivity automatic adjustment, 1, 2, 3 step: 1
14. Comfort level off, 1, 2, 3 step: 1
15. Humidifier 0 ~ 5 step: 1
16. Automatic function on/off
17. Pressure limit 20 ~ 35 cmH2O step: 0.5 cmH2O
Monitoring parameters
1. Frequency (Freq) 0 ~ 100 bpm Resolution: 1 bpm
2. Tidal volume (VT) 0 ~ 2000 mL Resolution: 1 mL
3. Minute ventilation (MV) 0 ~ 99 L/min ≥10 L/min, 0.1 L/min; <10 L/min, 0.01 L/min
4. Inspiratory time (Time) 0.0 ~ 3.0 S Resolution: 0.1 S
5. Inspiratory pressure (IPAP) 0 ~ 40 cmH2O Resolution: 0.5 cmH2O
6. Expiratory pressure (EPAP) 0 ~ 40 cmH2O Resolution: 0.5 cmH2O
7. Positive airway pressure (CPAP) 4 ~ 20 cmH2O Resolution: 0.5 cmH2O
Five, graphic display
1. Airway pressure-time waveform
2. Flow-time waveform
6. Alarm and protection
1. Asphyxia alarm [Asphyxia lasts for 8 s~12 s, and there is no exhalation]
2. Pipe falling off alarm [When the breathing tube is disconnected, and it lasts for 16s]
3. Alarm system silence (silence) [Alarm silence time: ≤120 s]
4. Low ventilation alarm [range: off, 0 L/min~15 L/min]
5. High breathing rate alarm Range: Off, 1 bpm ~ 99 bpm
6. Low breathing rate alarm Range: Off, 1 bpm ~ 60 bpm
7. Airway high pressure alarm Range: 20 cmH2O ~ 35 cmH2O
8. Power failure alarm
9. Low tidal volume alarm [When AVAPS is turned on]