Type: Ventilator
Kind: Gynaecology
Certification: CE, ISO13485
Group: Adult
LCD Display: With LCD Display
OEM: Yes
Customization:
Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
S1200
Application
ICU and Operation Room
Transport Package
Standard Packing
Specification
L560*W 560*H 605mm; 670*700*1160mm
Trademark
Superstar
Origin
China
HS Code
9019200000
Production Capacity
100/Month

Product Description

Medical equipment respiratory ventilator machine system
China Factory High End mechanical Ventilator for ICU/Nicu with CE

 Application
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.

Features
  1. 15" TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.
  2. Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
  3. Integration breathing circuit design.
  4. Multiple working modes such as volume control and pressure limit.
  5. Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.
  6. Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.
  7. Electrical PEEP control
  8. Breathing valve is disassembly and can be disinfected.

Safety
  1. Three levels alarm system, visual and sound alarm information.
  2. With multiple type of alarms, reminding and protection functions.
  3. Self-check before running, eliminate system mulfuction.
  4. Advanced power management control technology.
  5. With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.
  6. Separate design of electric and gas, keep safety running of ventilator.


Specifications
Ventilation modes: IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV
Ventilator parameter ranges  
Tidal volume(Vt) 0 ~ 2000mL
Frequency (Freq)
Oxygen concentration
1bpm ~ 100 bpm
21%-100%
I/E 4:1~1:8
PEEP 0cmH2O ~ 40 cmH2O
Pressure Limit 20 cmH2O ~ 100 cmH2O
Monitored Parameters  
Frequency (Freq) 0 /min ~ 100 /min
Tidal volume(Vt) 0 mL ~ 2500 mL
MV
Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
0 L/min ~ 99 L/min
0 cmH2O ~ 100 cmH2O
1mL/cmH2O ~ 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration 15 % ~ 100 %
 
Oscillographs display:  
P-T(pressure - time)  
F-T(flow - time)  
P-V loop (pressure - volume loop)  
V-T(volume - time )  
ETCO2-T (End-tidal CO2 - time)  
   
Alarms and protection  
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm ≤11.3±0.3V
No tidal volume No tidal volume within 6s
High Minute Volume alarm
Low Minute Volume alarm
5L/min-99L/min
1L/min-30L/min
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
19%-100%
18%-99%
Continuous pressure alarm (PEEP+1.5cmH2O) over 16s
Suffocation warning
Fan error
Oxygen deficit
                5-60s
Show on screen
Show on screen
The maximum limited pressure <12.5 kPa
   
Working conditions  
Gas source O2, AIR
Pressure 280kPa-600kPa
Voltage ~220V±22V
Power frequency 50Hz ± 1Hz
Input power 900VA (with air compressor)
250VA (without air compressor)
Ventilation modes: IPPV, A/C, PCV, SIMV, SPONT/CPAP, PSV
Ventilator parameter ranges  
Tidal volume(Vt) 0 ~ 2000mL
Frequence (Freq)
Oxygen concentration
1bpm ~ 100 bpm
21%-100%
I/E 4:1~1:8
PEEP 0cmH2O ~ 40 cmH2O
Pressure Limit 20 cmH2O ~ 100 cmH2O
Monitored Parameters  
Frequence (Freq) 0 /min ~ 100 /min
Tidal volume(Vt) 0 mL ~ 2500 mL
MV
Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
0 L/min ~ 99 L/min
0 cmH2O ~ 100 cmH2O
1mL/cmH2O ~ 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration 15 % ~ 100 %
 
Graphical display:  
P-T(pressure - time)  
F-T(flow - time)  
P-V loop (pressure - volume loop)  
V-T(volume - time )  
ETCO2-T (End-tidal CO2 - time)  
   
Alarm and protection  
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm ≤11.3±0.3V
No tidal volume No tidal volume within 6s
High Minute Volume alarm
Low Minute Volume alarm
5L/min-99L/min
1L/min-30L/min
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
19%-100%
18%-99%
Continuous pressure alarm (PEEP+1.5cmH2O) over 16s
Suffocation warning
Fan error
Oxygen deficit
                5-60s
Show on screen
Show on screen
The maximum limited pressure <12.5 kPa
   
Working conditions  
Gas source O2,AIR
Pressure 280kPa-600kPa
Voltage ~220V ±22V
Power frequency 50Hz ± 1Hz
Input power 900VA (with air compressor)
250VA (without air compreesor)

China Factory High End mechanical Ventilator for ICU/Nicu with CE
FAQ

Q:Do you have any sole agent in the world ? 
For DM6B Veterinary Anesthesia machine, we have sole agent in Mexico , other countries not yet now .


Q:If clients arrange engineers go to your company for training , is it for free ?
For cooperated clients, engineer's accommodation and meals are for free;
For potential customer, only meals for free, clients should pay for engineer's accommodation.


Q:How can we get the VISA / Invitation to visit your company ?
We will do the files for you in Nanjing city , and scan such files to you , go to the Chinese Embassy nearest of your city to get the VISA then .

Q:Do you have any clients in Africa?
Yes, we have . Our products have been sold to more than 200 countries, every client give us great feedback. With good quality and the best services, we have owned our customers' praise.

Q:How to be a agent of your company ?
Thank you so much . You can place a trial order of our products, and do the marketing research to see whether the products have good market demand, if yes, welcome to discuss the details with us . 

Q:How many certificates do you have ?
ISO9001,ISO13485, Free Sale certificate, CE certificate

Q:How can I pay for the equipment?
You can pay Dollar,Euro,RMB by T/T,West Union or L/C to our bank as you want.

Q:How can I get the machine to my country?
1. By air ( if time is urgent)
2. By sea ( if time is enough)
3. By express ( If the port is far away from hospital)
We can suggest suitable shipping cost for you according our forwarder's suggestion and your detailed address.
Of cause,you can use your own forwarder in China.You just need to tell us the contact of your forwarder and we send the equipment to him/her.

Q:How to install the machines?
All the ICU products are easy to install with our installation video . Every model have the video ,we will send to clients before install it .

Q:Do you have engineer can come to our location for installation ? 
Of course . Engineer can speak English very well and have passport so they can go everywhere at anytime .
Clients need to be in charge of their air tickets ,accommodation and meals if Q'ty is not too big .


China Factory High End mechanical Ventilator for ICU/Nicu with CE

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
215
Year of Establishment
2008-01-18