Type: | Special Animal Anesthesia Machine |
---|---|
Syringe: | Disposable Sterile Syringe |
Blood Sampling Needle: | The Tube Hard Tube |
Breathing Pattern: | Auto-Control |
Animal Anesthesia Machine Control Method: | Constant Volume |
Transport Package: | Wooden Case |
Customization: |
---|
Suppliers with verified business licenses
DM-6B Veterinary Anesthesia System
Friendly Powerful Reliable
The Veterinary Anesthesia machine makes a good performance in animal clinics. From high to low acuity, simple to complex cases, small to big animals, Perlong Medical Anesthesia Systems offer you the choices you need in ventilation, monitoring and technique. what's more, our expertise in anesthesia delivery and ventilation is based on rich 23-year history of developing anesthesia solutions that meet your needs. Good performance based onHigh Security, High Accuracy, High Stability and accurate monitoring.
Item No: | DM6B |
Ventilation mode | |
IPPV, A/C, PCV, SIMV, SIGH, MANUAL | |
Ventilator parameter range | |
Flowmeter | O2 (0.1 ~ 10 L/min) |
Rapid oxygen supply | 25 L/min ~ 75 L/min |
Tidal volume(Vt) | 20 mL ~ 1500 Ml |
Frequence(Freq) | 1 /min ~ 100 /min |
I:E | 2:1 ~ 1:6 |
Pressure triggering sensitivity(PTr) | -20 cmH2O~0 cmH2O (Based on PEEP) |
Flow trigger sensitivity (FTr) | 0.5 L/min ~ 30 L/min |
Pressure control (PC) | 5 cmH2O ~ 60 cmH2O |
SIGH | 0 (off) 1/100 ~ 5/100 |
Apnea ventilation | OFF, 5 s ~ 60 s |
Pressure limit | 20 cmH2O ~ 100 cmH2O |
Monitoring parameter | |
Frequence(Freq) | 0 /min ~ 100 /min |
Tidal volume (Vt) | 0 mL ~ 2000 mL |
MV | 0 L/min ~ 100 L/min |
Oscillogram | |
P-T (pressure - time) | |
F-T (flow - time) | |
Alarm and protection | |
The AC power failure alarm | Power failure or no connection |
Low voltage alarm for back up battery | < 11.3 ± 0.3 V |
No tidal volume | ≤ 5 mL within 6 s |
High oxygen concentration alarm | 19% ~ 100% |
Low oxygen concentration alarm | 18% ~ 99% |
High airway pressure alarm | 20cmH2O ~ 100cmH2O |
Low airway pressure alarm | 0cmH2O ~ 20cmH2O |
High minute volume alarm | Adult (5 L/min ~ 20 L/min) |
Low minute volume alarm | Paediatric (1L/min-15L/min) (0-10L/min) |
Continuous pressure alarm | (PEEP+1.5kPa) over 16s |
Suffocation warning | 5s-60s no spontaneous ventilation |
The maximum limited pressure | <12.5 kPa |
Fan error | Show on screen |
Oxygen deficit | Show on screen |
Working condition | |
Gas source | O2 |
Pressure | 280 kPa ~ 600 kPa |
Voltage | 100 ~ 240 V |
Power frequency | 50/60 Hz |