Type: Anesthesia Ventilator, Ventilator
Certification: CE, FDA, ISO13485
LCD Display: With LCD Display
Anesthesia: Semi Open Suction
Type of Operating Light: Double Operating Light
Kind: Ventilator
Customization:

Contact Supplier

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
S1200
Group
Adults and Children
Source
Air, O2
Transport Package
Wooden Case
Trademark
Superstar
Origin
Nanjing of China
HS Code
90192000
Production Capacity
5000 Units

Product Description

S1200 ICU Ventilator
ADULT · PEDIATRIC
Friendly Powerful Reliable

Ventilator Breathing Circuit Anesthesia Ventilator S1200



 
Application
The ventilator is suitable for various kinds of medical institutions for cardiopulmonary resuscitation respiratory support. Acute respiratory failure caused by various reasons or incomplete oxygenation dysfunction. Indra-operation, post-operation respiratory support, other respiratory treatment.
 
Features
l 15" TFT LCD touch screen displays the ventilation parameters, alarm information and waveforms.
l Air compressor runs stably with low noise, creates quiet environment for doctors and patients.
l Integration breathing circuit design.
l Multiple working modes such as volume control and pressure limit.
l Multiple parameters monitoring interface to show clear parameter to the operator, allow operator know the patient conditions in all aspects.
l Real time pressure-time, flow-time loop graphics, pressure volume loop graphics and high precision ETCO2, O2 concentration detection function included.
l Electrical PEEP control
l Breathing valve is disassembly and can be disinfected.
 
Safety
l Three levels alarm system, visual and sound alarm information.
l With multiple type of alarms, reminding and protection functions.
l Self-check before running, eliminate system mulfuction.
l Advanced power management control technology.
l With built-in backup power supply, when normal power supply shut down, back-up power supply will start work automatically.
l Separate design of electric and gas, keep safety running of ventilator.
 
Specifications
Ventilation modes: IPPVA/CPCVSIMVSPONT/CPAPPSV
Ventilator parameter ranges  
Tidal volume(Vt) 2000mL
Frequency (Freq)
Oxygen concentration
1bpm 100 bpm
21%-100%
I/E 4:1~1:8
PEEP 0cmH2O 40 cmH2O
Pressure Limit 20 cmH2O 100 cmH2O
Monitored Parameters  
Frequency (Freq) 0 /min 100 /min
Tidal volume(Vt) 0 mL 2500 mL
MV
Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
0 L/min 99 L/min
0 cmH2O 100 cmH2O
1mL/cmH2O 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration 15 % 100 %
 
Oscillographs display:  
P-T(pressure - time)  
F-T(flow - time)  
P-V loop (pressure - volume loop)  
V-T(volume - time )  
ETCO2-T (End-tidal CO2 - time)  
   
Alarms and protection  
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm ≤11.3±0.3V
No tidal volume No tidal volume within 6s
High Minute Volume alarm
Low Minute Volume alarm
5L/min-99L/min
1L/min-30L/min
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
19%-100%
18%-99%
Continuous pressure alarm (PEEP+1.5cmH2O) over 16s
Suffocation warning
Fan error
Oxygen deficit
                5-60s
Show on screen
Show on screen
The maximum limited pressure <12.5 kPa
   
Working conditions  
Gas source O2, AIR
Pressure 280kPa-600kPa
Voltage ~220V±22V
Power frequency 50Hz ± 1Hz
Input power 900VA (with air compressor)
250VA (without air compressor)
Ventilation modes: IPPVA/CPCVSIMVSPONT/CPAPPSV
Ventilator parameter ranges  
Tidal volume(Vt) 2000mL
Frequence (Freq)
Oxygen concentration
1bpm 100 bpm
21%-100%
I/E 4:1~1:8
PEEP 0cmH2O 40 cmH2O
Pressure Limit 20 cmH2O 100 cmH2O
Monitored Parameters  
Frequence (Freq) 0 /min 100 /min
Tidal volume(Vt) 0 mL 2500 mL
MV
Airway pressure
Dynamic lung compliance testing
ETCO2 Concentration
0 L/min 99 L/min
0 cmH2O 100 cmH2O
1mL/cmH2O 1000mL/cmH2O
0mmHg ~ 152mmHg (0%-20%)
Oxygen concentration 15 % 100 %
 
Graphical display:  
P-T(pressure - time)  
F-T(flow - time)  
P-V loop (pressure - volume loop)  
V-T(volume - time )  
ETCO2-T (End-tidal CO2 - time)  
   
Alarm and protection  
The AC power failure alarm Power failure or no connection
Internal battery backup low voltage alarm ≤11.3±0.3V
No tidal volume No tidal volume within 6s
High Minute Volume alarm
Low Minute Volume alarm
5L/min-99L/min
1L/min-30L/min
High Airway pressure alarm
Low Airway pressure alarm
High oxygen concentration alarm
Low oxygen concentration alarm
20cmH2O-100cmH2O
0cmH2O-20cmH2O
19%-100%
18%-99%
Continuous pressure alarm (PEEP+1.5cmH2O) over 16s
Suffocation warning
Fan error
Oxygen deficit
                5-60s
Show on screen
Show on screen
The maximum limited pressure <12.5 kPa
   
Working conditions  
Gas source O2,AIR
Pressure 280kPa-600kPa
Voltage ~220V ±22V
Power frequency 50Hz ± 1Hz
Input power 900VA (with air compressor)
250VA (without air compreesor)
 
Ventilator Breathing Circuit Anesthesia Ventilator S1200



 
Nanjing Superstar Medical Equipment Co., Ltd. 
Address: No.6 Building, No.9 Bofu Road, Yanjiang Industrial Development Zone, Liuhe District, 211505 Nanjing, P.R. China
Tel: +86-25-69658833  Fax: +86-25-69658833
http://superstar2018.en.made-in-china.com  
 
 

Send your message to this supplier

*From:
*To:
avatar Miss Diana Wu
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Contact Supplier

Diamond Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
215
Year of Establishment
2008-01-18