Nanjing Superstar Medical Equipment Co., Ltd.
Jiangsu, China
Diamond Member Since 2018
Audited Supplier
Manufacturer/Factory & Trading Company
Sample Available
OEM/ODM Service
French / Spanish Speaker
Factory Tour
MEI Awards
S6600 High-Technology ISO Ce Medical Anesthesia Machine
Reference FOB Price: | US $10,000.00-15,000.00 / Piece |
---|---|
Min. Order: | 1 Piece |
Type: | Anaesthesia Machine |
---|---|
Kind: | Gynaecology |
Certification: | CE, ISO13485 |
Group: | Adult |
LCD Display: | With LCD Display |
OEM: | Yes |
Basic Info
Model NO.
S6600
Transport Package
Standard Export Packing
Specification
870*960*1600mm
Trademark
Superstar
Origin
China
HS Code
9018907090
Production Capacity
100/Month
Product Description
S6600 high-technology ISO CE medical anesthesia machine
Configuration
Technical Specification
2.1 Adjusting Parameter
Tidal Volume:10mL~1500mL;
Inspiration pressure: 1cmH2O;
Pressure support:3cmH2O~50cmH2O;
Pressure limit: 10cmH2O~100cmH2O;
PEEP: 0cmH2O~30cmH2O;
Respiration frequency:4bpm~100bpm;
Inspiration apnea: OFF, 5%~60%;
I:E:4:1~1:10;
Inspiration time: 0.2s~5s;
Trigger:5%~95%;
SIMV frequency:4bpm~60bpm;
Pressure trigger: -1cmH2O~-20cmH2O;
Flow trigger: 0.3 L/min,1L/min~15L/min;
Rise time:0s~2s;
2.2 Monitoring parameter
Tidal volume:0mL~2500mL;
Minute volume:0L/min~100L/min;
Respiration frequency:0bpm~120bpm;
Oxygen concentration:15%~100%(V/V)
Airway pressure:-20cmH2O~100cmH2O;
Inspiration platform pressure:0cmH2O~100cmH2O;
PEEP:0cmH2O~70cmH2O;
I:E:4:1~1:10;
Resistance:0 cmH2O/(L/s)~250 cmH2O/(L/s);
Compliance:0 ml/cmH2O~250 ml/cmH2O;
AG(optional)
CO2: 0%~15%(V/V);
N2O: 0%~100%(V/V);
Enflurane,Isoflurane: 0%~8%(V/V);
Sevoflurane: 0%~10%(V/V);
2.3 Alarm
VT UPPER LIMIT:5mL~2000mL;
VT LOWER LIMIT:0mL~1595mL;
MV upper limit:0.1L/min~100L/min;
MV lower limit:0.0L/min~99.9L/min;
Respiration frequency upper limit:2bpm~100bpm;
Respiration frequency lower limit:0bpm~98 bpm;
FIO2 upper limit:20%~100%;
FIO2 lower limit:18%~98%;
Airway pressure upper limit:2cmH2O~100cmH2O;
Airway pressure lower limit:0cmH2O~98cmH2O;
Apnea:20s~40s.
Oxygen concentration never lower than 25% when N2O start
2.4 Testing
Automatic leakage compensation testing.
Patient circuit leakage compensation and automatic compliance compensation.
Patient monitor and AG monitor can be equipped.
Manual ventilator, mechanical ventilation and standby.
Waveform:P-T, F-T, V-T, Lung function loop, ETCO2, Anesthesia gas, oxygen concentration, N2O concentration.
Self-testing visible
Alarming visible
ACGO function
2.5 Battery working
There are two battery inside, use one of them can last long for no less than 60 mins, when use two, it can last long for no less than 120 mins.
Configuration
NO. | Items | * Including ★optional | |
1 | Ventilation modes | Manual | * |
(V-CMV)IPPV | * | ||
(P-CMV)PCV | * | ||
(P-S1MV)(V-S1MV) | * | ||
PSV | * | ||
PRVC | * | ||
2 | Monitoring Parameters | Tidal Volume | * |
Minute Volume | * | ||
PEEP | * | ||
Airway pressure | * | ||
Respiratory frequency | * | ||
I:E | * | ||
Resistance | * | ||
Compliance | * | ||
Oxygen concentration | * | ||
3 | Waveform | P-T | * |
F-T | * | ||
V-T | * | ||
Lung function loop | * | ||
ETCO2 waveform | * | ||
4 | Function | AG monitoring | ★ |
ETCO2 | * | ||
AGSS | ★ | ||
Electronic monitoring gas source pressure | * | ||
Mechanical/Electronic rapid oxygen | * | ||
ACGO | * | ||
Assist air supply/oxygen supply | * | ||
Built-in battery | * | ||
2.1 Adjusting Parameter
Tidal Volume:10mL~1500mL;
Inspiration pressure: 1cmH2O;
Pressure support:3cmH2O~50cmH2O;
Pressure limit: 10cmH2O~100cmH2O;
PEEP: 0cmH2O~30cmH2O;
Respiration frequency:4bpm~100bpm;
Inspiration apnea: OFF, 5%~60%;
I:E:4:1~1:10;
Inspiration time: 0.2s~5s;
Trigger:5%~95%;
SIMV frequency:4bpm~60bpm;
Pressure trigger: -1cmH2O~-20cmH2O;
Flow trigger: 0.3 L/min,1L/min~15L/min;
Rise time:0s~2s;
2.2 Monitoring parameter
Tidal volume:0mL~2500mL;
Minute volume:0L/min~100L/min;
Respiration frequency:0bpm~120bpm;
Oxygen concentration:15%~100%(V/V)
Airway pressure:-20cmH2O~100cmH2O;
Inspiration platform pressure:0cmH2O~100cmH2O;
PEEP:0cmH2O~70cmH2O;
I:E:4:1~1:10;
Resistance:0 cmH2O/(L/s)~250 cmH2O/(L/s);
Compliance:0 ml/cmH2O~250 ml/cmH2O;
AG(optional)
CO2: 0%~15%(V/V);
N2O: 0%~100%(V/V);
Enflurane,Isoflurane: 0%~8%(V/V);
Sevoflurane: 0%~10%(V/V);
2.3 Alarm
VT UPPER LIMIT:5mL~2000mL;
VT LOWER LIMIT:0mL~1595mL;
MV upper limit:0.1L/min~100L/min;
MV lower limit:0.0L/min~99.9L/min;
Respiration frequency upper limit:2bpm~100bpm;
Respiration frequency lower limit:0bpm~98 bpm;
FIO2 upper limit:20%~100%;
FIO2 lower limit:18%~98%;
Airway pressure upper limit:2cmH2O~100cmH2O;
Airway pressure lower limit:0cmH2O~98cmH2O;
Apnea:20s~40s.
Oxygen concentration never lower than 25% when N2O start
2.4 Testing
Automatic leakage compensation testing.
Patient circuit leakage compensation and automatic compliance compensation.
Patient monitor and AG monitor can be equipped.
Manual ventilator, mechanical ventilation and standby.
Waveform:P-T, F-T, V-T, Lung function loop, ETCO2, Anesthesia gas, oxygen concentration, N2O concentration.
Self-testing visible
Alarming visible
ACGO function
2.5 Battery working
There are two battery inside, use one of them can last long for no less than 60 mins, when use two, it can last long for no less than 120 mins.